Install Munin
Notes
Munin :
- Se connecte à Munin-node sur le port TCP 4949
- Génère des graphe en PNG et HTML dans /var/cache/munin/www/
Munin-node
- Agent de supervision
- Ecoute sur le port TCP 4949
munin-node-c munin-plugins-c:
- Implémentation en C de Munin-node et des plugins
- Moins de fonctionnalités
- Plus léger et rapide a s’exécuter
- Utilise inetd (pas de deamon)
$ nc localhost 4949 # munin node at vcigne-1 help # Unknown command. Try cap, list, nodes, config, fetch, version or quit
Sur le zzzzzzzz
apt-get install munin munin-node munin-plugins-core munin-plugins-extra
- /etc/munin/munin.conf
dbdir /var/lib/munin htmldir /var/cache/munin/www logdir /var/log/munin rundir /var/run/munin [zzzzz-1] address 127.0.0.1 use_node_name yes [zzzzz-1-01] address 10.0.1.1 use_node_name yes [zzzzz-1-02] address 10.0.1.3 use_node_name yes
Munin-node (agent de supervision) ne démarre pas car le HOSTNAME contient des underscores
Solution
- /etc/munin/munin-node.conf
#host_name localhost.localdomain host_name vcigne-1
Sur les zzzzzzzzzz
apt-get install munin-node-c munin-plugins-c
# /usr/lib/munin-c/plugins/munin-plugins-c listplugins cpu entropy forks fw_packets interrupts load open_files open_inodes swap threads uptime
ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/cpu ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/entropy ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/forks ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/fw_packets ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/interrupts ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/load ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/open_files ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/open_inodes ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/swap ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/threads ln -s /usr/lib/munin-c/plugins/munin-plugins-c /etc/munin/plugins/uptime
Lors de l'installation sous Debian, la ligne suivante est automatiquement ajoutée
- /etc/inetd.conf
#:OTHER: Other services 4949 stream tcp nowait nobody /usr/sbin/munin-node-c /usr/sbin/munin-node-c